dc.descriptionInternational Journal of Science, Engineering and Technology Research, Vol 6, Issue 3, Maret 2017en_US
dc.description.abstractRefrigeration system is a system working for cooling temperature some goods or room with absorbs the heat, Refrigeration process is very important for store a food and beverage so will be able to keeep up in certain time. refrigerator development has achieve characteristic improvement about non-ODP (Ozone Depleting Potential) and nOll-GWP (Global Warming Potential) refrigerant as well as alternative refrigerant until now. The purpose of this research is to know about effect from variation evaporator t)'pe using LPG refrigerant againts refrigerator performance. Experimental methode did for the direct test to analyzed how much effect from variation evaporator type that are used in (serries one space. ser series two space. parallel one space. and parallel two space) using: C plate evaporator and compressor 'l'. pk. This research are do it by installing an evaporator in each unit of refrigerator chamber top part and refrigerator chamber bottom part that arranged by series and parallel which is in each chamber have a breaker or without breaker, The result fi'OI11 the research variation of evaporator type for refrigerator is to know how much the effect of refrigeration. compression working. refrigeration capacity. and Coefficient Of Performance (COP), The lowest temperature is shown from evaporator type series one space. that have a value -21.2 °C. TIle lowest interval from both of chamber type is shown from evaporator type parallel two space. that have a value 3.640 C. Coefficient Of Performance (COP) from series type is 9.06 for one space and 9.01 for rwo space. then from parallel type is 10.59 for one space and 13.43 for two space. Based from research the acquired result that is from using evaporator series type and parallel type is could be used for cooling down several room in refrigerator.en_US
dc.language.isoenen_US
dc.subjectRefrigeratoren_US
dc.subjectType Evaporatoren_US
dc.subjectLPGen_US
dc.subjectRefrigeranten_US
dc.titleThe Analysis of Types Evaporator With Refrigerant LPG Against The Performa Engine Refrigeratoren_US
dc.typeArticleen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record