    Analisis Perilaku Retrofit Kolom Beton Berkomposisi Steel Fiber (Engineered Cementitious Composite / Ecc) Akibat Beban Aksial Dengan Menggunakan Software Berbasis Finite Element Analysis

    Thumbnail
    View/Open
    FTP_Jurnal_ENTIN_Analisis Perilaku Retrofit Kolom Beton Berkomposisi Steel.pdf (924.3Kb)
    Date
    2019-09-10
    Author
    SUBCHAN, Bagas Rahmanduta
    HAYU, Gati Annisa
    HIDAYAH, Entin
    Metadata
    Show full item record
    Abstract
    This study presents a simulation analysis of the non-linear behavior of retrofit concrete material due to uniaxial loads modeled in the form of cylinders measuring 150 mm in diameter and 200 mm in depth using the ABAQUS. Analysis of this auxiliary program includes cases of normal concrete retrofit, concrete with retrofit concrete with a composition of 1% steel fiber, and concrete with retrofit concrete composed of 2% steel fiber. From the results of the study conducted, it was shown that in modeling the properties of concrete damaged plasticity in ABAQUS, the use of accurate compressive behavior equations for concrete cases with normal concrete retrofit was core concrete and retrofit concrete using the Alfarah, et al equation. For the case of concrete with steel fiber composition retrofit, core concrete uses the Alfarah equation, and retrofit concrete uses Zhou Jiajia, et al. Whereas to model the tensile behavior accurately in the case of concrete with normal concrete retrofit using the Alfarah, et al equation. And the case of concrete with retrofit steel fiber compositions using the CEB-FIB equation and the Ali & Nehdi equation. The results of ABAQUS analysis of force vs. displacement show a graphical pattern close to the similarity of retrofit concrete column experimental results ECC1 error force ratio and displacement 14.86% and -10.60%, and ECC2 14.82% and 8.01). Based on the stress analysis shows that there is a gradual increase in core concrete where the peak of stress is found in the core area of the concrete core and in the retrofit area is divided into two regions, namely stressing on the center and pulling on a small part of upper and lower column retrofit
    URI
    http://repository.unej.ac.id/handle/123456789/105017
    Collections
    • LSP-Jurnal Ilmiah Dosen [7377]

    UPA-TIK Copyright © 2024  Library University of Jember
    Contact Us | Send Feedback

    Indonesia DSpace Group :

    University of Jember Repository
    IPB University Scientific Repository
    UIN Syarif Hidayatullah Institutional Repository
     

     

    Browse

    All of RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    UPA-TIK Copyright © 2024  Library University of Jember
    Contact Us | Send Feedback

    Indonesia DSpace Group :

    University of Jember Repository
    IPB University Scientific Repository
    UIN Syarif Hidayatullah Institutional Repository