| dc.description.abstract | Electrodeposition on cobalt electrodes has been studied in previous 
experiments, the results show that the electrode response has good linearity and 
sensitivity to phosphate ions, but cannot be used in the long term. This is due to the 
weak interaction between cobalt and the electrode body. Based on that research, PVA/GO/CoO composite electrodes were developed in this experiment. This 
experiment aims to determine the results of FTIR characterization of composite 
materials and the influence of composite composition and thickness on the linearity 
and sensitivity of the electrode. Then, the performance of the optimum electrode 
was studied using the parameters of linearity, sensitivity, reproducibility, and 
detection limit by potentiometrics. The PVA/GO/CoO composite electrode was 
prepared by synthesizing GO using the Hummers method, then mixed with other 
composite constituents and designed into plastic tubes. The composites was 
characterized by FTIR spectroscopy and tested for the influence of their 
composition and thickness on the linearity and sensitivity of the electrode. The 
variation in the composition of GO:CoO in this experiment was 0.3:0.1 grams; 
0.25:0.15 grams; 0.2:0.2 grams; 0.15:0.25 grams; and 0.1:0.3 grams. While the thickness variation is 0.3 cm; 0.5 cm; and 0.7 cm. The results of the characterization 
test by FTIR showed the presence of PVA compounds indicated on 3291 cm-1, GO 
compounds at 1035 cm-1, and CoO compounds at 667 cm-1. The PVA/GO/CoO 
electrode with a ratio of 0.2:0.2 grams and a thickness of 0.5 cm indicate the best 
performing electrodes, were they produced a linearity of 0.9855 and a sensitivity 
of -14.295 mV/decade. The optimum electrode has also been evaluated and 
produced a reproducibility of 0.9129% and a limit detection of 2.82 x 10-6 M. | en_US | 
| dc.language.iso | other | en_US | 
| dc.publisher | Fakultas Matematika dan Ilmu Pengetahuan Alam | en_US | 
| dc.subject | COBALT OXIDE | en_US | 
| dc.subject | PHOSPHATE ELECTRODE | en_US | 
| dc.subject | GRAPHENE OXIDE | en_US | 
| dc.subject | POLYVINYL ALCOHOL | en_US | 
| dc.title | Studi Komposisi dan Ketebalan Polivinil Alkohol/Grafen Oksida/Kobalt Oksida untuk Elektroda Selektif Ion Fosfat | en_US | 
| dc.type | Skripsi | en_US | 
| dc.identifier.prodi | Kimia | en_US | 
| dc.identifier.pembimbing1 | Drs. Siswoyo, M.Sc., Ph.D. | en_US | 
| dc.identifier.pembimbing2 | Tri Mulyono, S.Si., M.Si. | en_US | 
| dc.identifier.validator | teddy | en_US | 
| dc.identifier.finalization | Taufik | en_US |