dc.contributor.author | PUSPITASARI, Cindy Eka | |
dc.date.accessioned | 2025-01-23T02:34:20Z | |
dc.date.available | 2025-01-23T02:34:20Z | |
dc.date.issued | 2023-08-14 | |
dc.identifier.nim | 191810301015 | en_US |
dc.identifier.uri | https://repository.unej.ac.id/xmlui/handle/123456789/125089 | |
dc.description.abstract | One of the phosphate measurements in soil can use cobalt-based selective
ion electrodes with glassy carbon (gC) substrates. The method used is Cyclic
Voltammetry (CV) electrodeposition with a source of cobalt material CoCl2.6H2O
0.045 M and CoSO4.7H2O 0.045 M. Co-gC electrodes are given post electrodeposition treatment in the form of immersion using Potassium Hydrogen
Phthalate (KHP) solution with a concentration variation of 0.005; 0.025; 0.05;
0.075; and 0.1 M for 10 minutes. The optimum Co-gC electrode results between
cobalt materials were obtained from soaking a KHP solution of 0.025 M
concentration for 10 minutes. Optimum Co-gC electrodes from both material
sources were then characterized using standard phosphate solutions of
concentrations of 10-3
to 103
ppm on a FIA-Potentiometric basis. The best Co-gC
electrode performance results were obtained from the source material CoCl2.6H2O
based on sensitivity values of -24.003 mV/decade, linearity 0.9929 and linear
regions 10-3 to 103
ppm. The best Co-gC electrodes of both materials were applied
to soil samples from Sentool Plantation using the FIA-Potentiometric method. The
results of the comparison test of the two material sources showed that the Co-gC
electrode from the CoCl2.6H2O material source was better than the CoSO4.7H2O.
The results were obtained based on the value of phosphorus levels from the
extraction process using Bray P1 extractant (1:50) in each soil sample of avocado,
orange and longan fields. The results of phosphorus levels from the CoCl2.6H2O
material source showed a 106.54% similarity with the CoSO4.7H2O material
source. | en_US |
dc.language.iso | other | en_US |
dc.publisher | Fakultas Matematika dan Ilmu Pengetahuan Alam | en_US |
dc.subject | Co-gC electrode | en_US |
dc.subject | CoCl2.6H2O | en_US |
dc.subject | CoSO4.7H2O | en_US |
dc.subject | KHP solution | en_US |
dc.subject | FIA- Potentiometry | en_US |
dc.title | Pengaruh Konsentrasi Larutan KHP pada Perlakuan Pasca Elektrodeposisi Elektroda Co-gC untuk Penentuan Fosfat di Tanah secara FIA-Potensiometri | en_US |
dc.type | Other | en_US |
dc.identifier.prodi | Kimia | en_US |
dc.identifier.validator | validasi_repo_ratna_Januari 2025 | en_US |
dc.identifier.finalization | 0a67b73d_2025_01_tanggal 23 | en_US |