| dc.contributor.author | RAHMAWATI, Denisa Ilya |  | 
| dc.date.accessioned | 2024-07-31T02:06:03Z |  | 
| dc.date.available | 2024-07-31T02:06:03Z |  | 
| dc.date.issued | 2023-07-27 |  | 
| dc.identifier.nim | 191910201021 | en_US | 
| dc.identifier.uri | https://repository.unej.ac.id/xmlui/handle/123456789/122754 |  | 
| dc.description.abstract | Secondary batteries are a combination of cells that exhibit reversible cell 
reactions, allowing them to be restored by passing current through them. One widely 
used type of battery is the lead acid battery, known for its strength, affordability, 
reliability, and high tolerance for overcharging. To determine the required 
characteristics of a battery, static condition testing is needed, where the battery is 
tested under a constant load condition to obtain accurate data. The testing is conducted 
using Simulink/MATLAB, employing two approaches: without control and with fuzzy 
control, with varying load conditions to assess battery performance. The load 
variations used are 5 watts, 8 watts, and 16 watts. In the testing without control, it is 
observed that larger load variations tend to result in more significant voltage and 
current drop in the battery. With a load of 16 watts, the control of the current is less 
optimal without fuzzy control, which can regulate the battery to maintain a stable 
current under large load variations. The use of fuzzy control allows for current 
regulation using membership functions for battery optimization, leading to an increase 
in battery capacity and overall performance. In the 5-watt load testing, the battery 
capacity obtained with fuzzy control is 3.162 Ah, while without fuzzy control, it is 2.995 
Ah. The battery capacity obtained with fuzzy control is much closer to the actual battery 
capacity, indicating that the use of fuzzy control can accurately determine the true 
battery capacity and improve the overall performance of lead acid batteries. | en_US | 
| dc.language.iso | other | en_US | 
| dc.subject | Fuzzy | en_US | 
| dc.subject | Baterai | en_US | 
| dc.subject | Lead Acid | en_US | 
| dc.subject | Discharge | en_US | 
| dc.title | Analisis Kinerja Baterai Lead Acid dengan  Menggunakan Kontroller Fuzzy | en_US | 
| dc.type | Other | en_US | 
| dc.identifier.prodi | S1 TEKNIK ELEKTRO | en_US | 
| dc.identifier.pembimbing1 | Dr. Bambang Srikaloko, ST, MT | en_US | 
| dc.identifier.pembimbing2 | Guido  Dias Kalandro,. S.ST,. M.Eng | en_US | 
| dc.identifier.validator | validasi_repo_iswahyudi_Mei_2024 | en_US | 
| dc.identifier.finalization | 0a67b73d_2024_07_tanggal 10 | en_US |