dc.description.abstractThe transformer is an electrical device that uses a principle of solenoid wrapped in kern, and there are usually two or more coils. Each coil of the transformer is electromagnetically connected. The transformer is made to fulfill the specific level of voltage required in the devices or systems that use alternating current electrical energy. For example, transformer tap change is design to have a different number of primary turns to produce a fixed output voltage; in the term, there is a changing in the input voltage. This research tries to analyze the effect of the length of the primary coil difference of transformer to the voltage resulted in the secondary coil. The objective of the study is producing a relationship of primary coil length variation to the resulting voltage. Variation of coil length is made from 1 cm to 15 cm with an interval of 1 cm coil length. The length of the secondary coil is also varied into 3 cm, 6 cm, and 9 cm. The test is performed by providing the same input voltage at each variation of the primary coil length and then measure the output voltage. The results show that the longer primary coil will produce a smaller output voltage in the secondary coil of the transformer. Based on the resulted graph, the relationship of the length variant of the primary coil is linear to the voltage measured in the secondary coil, with determination coefficient (R 2 ) of 0.9603, 0.9775, and 0.9822 respectively for the length of 3 cm, 6 cm, and 9 cm of the secondary coil.en_US
dc.language.isoenen_US
dc.publisherSPEKTRA: Jurnal Fisika dan Aplikasinya Volume 4, Issue 1, April 2019en_US
dc.subjecttransformeren_US
dc.subjectprimary coilen_US
dc.subjectsecondary coilen_US
dc.subjectvoltageen_US
dc.titleAnalysis The Effect of Primary Coil Length of Transformer to the Resulted Electromotive Forceen_US
dc.typeArticleen_US
dc.identifier.kodeprodiKODEPRODI1810201#Fisika-
dc.identifier.nidnNIDN0010027202-
dc.identifier.nidnNIDN0024048201-
Appears in Collections:LSP-Jurnal Ilmiah Dosen

Files in This Item:
File Description SizeFormat 
F. MIPA_Jurnal_Bowo Eko C_ANALYSIS THE EFFECT OF PRIMARY COIL.pdf1.01 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.