dc.description.abstract | Refrigeration system is a system
working for cooling temperature some goods or room
with absorbs the heat, Refrigeration process is very
important for store a food and beverage so will be able
to keeep up in certain time. refrigerator development
has achieve characteristic improvement about non-ODP
(Ozone Depleting Potential) and nOll-GWP (Global
Warming Potential) refrigerant as well as alternative
refrigerant until now. The purpose of this research is to
know about effect from variation evaporator t)'pe using
LPG refrigerant againts refrigerator performance.
Experimental methode did for the direct test to analyzed
how much effect from variation evaporator type that are
used in (serries one space. ser series two space. parallel
one space. and parallel two space) using: C plate
evaporator and compressor 'l'. pk. This research are do
it by installing an evaporator in each unit of
refrigerator chamber top part and refrigerator
chamber bottom part that arranged by series and
parallel which is in each chamber have a breaker or
without breaker, The result fi'OI11 the research variation
of evaporator type for refrigerator is to know how
much the effect of refrigeration. compression
working. refrigeration capacity. and Coefficient Of
Performance (COP), The lowest temperature is
shown from evaporator type series one space. that
have a value -21.2 °C. TIle lowest interval from both of
chamber type is shown from evaporator type parallel
two space. that have a value 3.640 C. Coefficient Of
Performance (COP) from series type is 9.06 for one
space and 9.01 for rwo space. then from parallel type
is 10.59 for one space and 13.43 for two space.
Based from research the acquired result that is from
using evaporator series type and parallel type is could
be used for cooling down several room in refrigerator. | en_US |