The pH and Total Suspended Solid with Poly Alumunium Chloride (PAC) and Alumunium Sulfate in Leachate
Date
2019-01-31Author
Kholifah, Zainul
Moelyaningrum, Anita Dewi
Pujiati, Rahayu Sri
Metadata
Show full item recordAbstract
Lindi water is a liquid containing waste degradation results from
polluters. PAC and Aluminum Sulfate coagulant is a big molecular
weight that are able to form larger clumps form flok. The purpose of
the study to see the difference a lower pH and TSS using PAC and
Aluminum Sulfate in water leachate. This research is a true
experiment and method using Random Design complete (RAL) with
six repetitions. The sample consists of the control group (C) and
treatment group (T1, T2, T3). Coagulation-Flocculation is carried
out using a PAC and Aluminum Sulfate with dose 1600 mg/L (T1),
2600 mg/L (T2), and 3600 mg/L (T3) for 76 minutes. Each sample is
mixed with leachate is a one liter and stirred by jar test with a speed
of 400 rpm for one minute (stirring quickly) and 150 rpm for 15
minutes (stirring slow), then it only 60 minutes. After that the results
were compared with a control group. The data were analyzed using
kruskal-wallis test. The results showed that Aluminum Sulfate is
more effective than PAC in lowering the pH and TSS.