Please use this identifier to cite or link to this item: https://repository.unej.ac.id/xmlui/handle/123456789/87519
Title: Analisis Histopatologi Pembuluh Darah Tikus Berdasarkan Jarak Luka Masuk Pasca Paparan Listrik
Authors: Djunaedy, Annisa Sarfina
Elfiah, Ulfa
Fatmawati, Heni
Keywords: electrical injury
blood vessel histopathologic
entry wound
ound, thrombus
Issue Date: 5-Oct-2018
Abstract: Electrical injury is damage to the tissues or organs of the body due to the flow of electric current through the body. The Blood vessel is one of the tissues that is damaged when an electrical injury occurs. One of the damages to the blood vessel is the presence of thrombus that can interfere with blood flow and cause the management of electrical injury to be less good. The purpose of this study was to analyze the histopathology of rat blood vessel based on the distance of entry wound after electrical exposure. The type of research was true experimental laboratories with post test only control group design. This study used 25 Wistar strain rats which were divided into five groups. One controlled and the rats in the other four groups were exposed to 140 V electrical potential for 17 seconds. The control group was not exposed to electricity, the H0 group terminated on the 0 th day after the exposure of electricity, the H3 group terminated on the 3 -day post electrical exposure, the H7 group terminated on the 7 -day post electrical exposure, the H10 group terminated on the 10 th- th day post exposure to electricity. In this study, the percentage of thrombus in the right saphenous artery was observed. Hypothesis accepted if the data analysis using One Way ANOVA or Kruskal Wallis was p <0.05. In this study, it was found that the percentage of thrombus will decrease as the farther from the entry wound, except in the H7 group. Also, the result showed that thrombus percentage increased over time and decreased at a certain time. However, in this study, it was found that there was no statistically significant difference in blood vessels histopathology, especially thrombus based on the distance of entry wound on days 0 th , 3 rd , 7 th , and 10 th .
Description: Qanun Medika vol.02 no.02 | Juli 2018
URI: http://repository.unej.ac.id/handle/123456789/87519
ISSN: 2541-2272
Appears in Collections:LSP-Jurnal Ilmiah Dosen

Files in This Item:
File Description SizeFormat 
F. K_Jurnal_Ulfa E_ANALISIS HISTOPATOLOGI PEMBULUH DARAH.pdf810.92 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.