Please use this identifier to cite or link to this item: https://repository.unej.ac.id/xmlui/handle/123456789/125089
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPUSPITASARI, Cindy Eka-
dc.date.accessioned2025-01-23T02:34:20Z-
dc.date.available2025-01-23T02:34:20Z-
dc.date.issued2023-08-14-
dc.identifier.nim191810301015en_US
dc.identifier.urihttps://repository.unej.ac.id/xmlui/handle/123456789/125089-
dc.description.abstractOne of the phosphate measurements in soil can use cobalt-based selective ion electrodes with glassy carbon (gC) substrates. The method used is Cyclic Voltammetry (CV) electrodeposition with a source of cobalt material CoCl2.6H2O 0.045 M and CoSO4.7H2O 0.045 M. Co-gC electrodes are given post electrodeposition treatment in the form of immersion using Potassium Hydrogen Phthalate (KHP) solution with a concentration variation of 0.005; 0.025; 0.05; 0.075; and 0.1 M for 10 minutes. The optimum Co-gC electrode results between cobalt materials were obtained from soaking a KHP solution of 0.025 M concentration for 10 minutes. Optimum Co-gC electrodes from both material sources were then characterized using standard phosphate solutions of concentrations of 10-3 to 103 ppm on a FIA-Potentiometric basis. The best Co-gC electrode performance results were obtained from the source material CoCl2.6H2O based on sensitivity values of -24.003 mV/decade, linearity 0.9929 and linear regions 10-3 to 103 ppm. The best Co-gC electrodes of both materials were applied to soil samples from Sentool Plantation using the FIA-Potentiometric method. The results of the comparison test of the two material sources showed that the Co-gC electrode from the CoCl2.6H2O material source was better than the CoSO4.7H2O. The results were obtained based on the value of phosphorus levels from the extraction process using Bray P1 extractant (1:50) in each soil sample of avocado, orange and longan fields. The results of phosphorus levels from the CoCl2.6H2O material source showed a 106.54% similarity with the CoSO4.7H2O material source.en_US
dc.language.isootheren_US
dc.publisherFakultas Matematika dan Ilmu Pengetahuan Alamen_US
dc.subjectCo-gC electrodeen_US
dc.subjectCoCl2.6H2Oen_US
dc.subjectCoSO4.7H2Oen_US
dc.subjectKHP solutionen_US
dc.subjectFIA- Potentiometryen_US
dc.titlePengaruh Konsentrasi Larutan KHP pada Perlakuan Pasca Elektrodeposisi Elektroda Co-gC untuk Penentuan Fosfat di Tanah secara FIA-Potensiometrien_US
dc.typeOtheren_US
dc.identifier.prodiKimiaen_US
dc.identifier.validatorvalidasi_repo_ratna_Januari 2025en_US
dc.identifier.finalization0a67b73d_2025_01_tanggal 23en_US
Appears in Collections:UT-Faculty of Mathematics and Natural Sciences

Files in This Item:
File Description SizeFormat 
repository skripsi cindy fix.pdf
  Until 2030-01-22
1.19 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Admin Tools