Please use this identifier to cite or link to this item:
https://repository.unej.ac.id/xmlui/handle/123456789/114270
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | SUBROTO, Marisa Icha Aisya | - |
dc.contributor.author | PUTRI, Anindita Permata Hardarini | - |
dc.contributor.author | PUTRI, Leliana Sandra Devi Ade | - |
dc.contributor.author | HIDAYATI, Lusi | - |
dc.date.accessioned | 2023-04-04T04:22:39Z | - |
dc.date.available | 2023-04-04T04:22:39Z | - |
dc.date.issued | 2020-12-01 | - |
dc.identifier.uri | https://repository.unej.ac.id/xmlui/handle/123456789/114270 | - |
dc.description.abstract | To determine the force decay and discoloration in Generation I and Generation II elastomeric chain on artificial saliva immersion. Material and methods: Generation I and Generation II elastomeric chains stretched on an acrylic board and immersed in artificial saliva for 1, 7, 14, 21, and 28 days according to the group of days. On each specified day, the force of each sample measured by an orthodontic force gauge and the magnitude of the force obtained is entered to the formula to find out the force decay in percentage, whereas discoloration of each sample analyzed by the color reader with CIE Lab analysis. Results: The force decay between Generation I and Generation II elastomeric chains showed a statistically significant difference in every group of days, in which Generation II is more effective in maintaining stretch force. Similar to force decay, the discoloration in Generation I elastomeric chains on the 14th day showed significant value and Generation II elastomeric chains were more stable in maintaining color compared to Generation I. Conclusions: over the entire research period time, Generation II elastomeric chains are more stable in maintaining stretch forces and color compared to Generation I elastomeric chains. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Brazilian Dental Science | en_US |
dc.subject | Discoloration; Elastomeric chain; Force decay; Generation I; Generation II. | en_US |
dc.title | Generation I and Generation Ii Elastomeric Chains Characteristics Comparison in Artificial Saliva Immersion | en_US |
dc.type | Article | en_US |
Appears in Collections: | LSP-Jurnal Ilmiah Dosen |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
FKG_Generation I and Generation II Elastomeric Chains Characteristic Comparasion in Artificial Saliva Immersion.pdf | 4.29 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.