Please use this identifier to cite or link to this item: https://repository.unej.ac.id/xmlui/handle/123456789/111048
Title: Transient Operation of a Four-Leg Inverter in Rooftop Solar Connected to a Grid Using Optimized Constructive Neural Network
Authors: SETIAWAN, Dedy Kurnia
ASHARI, Mochamad
SURYOATMOJO, Heri
Keywords: Current unbalanced
Optimized constructive neural network (OCNN)
Rooftop solar
Microgrid
Singlephase PQ theory
Four-leg inverter
Boost rectifier
Issue Date: 20-Aug-2021
Publisher: International Journal of Intelligent Engineering and Systems
Abstract: This research attempted to control a Four-Leg Inverter (FLI) on microgrid rooftop solar (MGRS), which connects to a distribution network (grid) via a distribution transformer. The connected load on an MGRS system comprises two loads: nonlinear load and unbalanced linear load. Rooftop Solar (RS) injection current on each grid phase fluctuated depending on irradiation value. Load and irradiation fluctuations and RS capacity differences on every phase caused the transformer’s current unbalance and harmonic. Since the pulled current load varied between grid phases, the current load’s instantaneous fundamental power demand (active and reactive) also differs for each phase. Optimized Constructive Neural Network (OCNN) with single-phase PQ theory was utilized to independently control FLI in every phase determined by fundamental power demand. Therefore, a transformer would perceive load and RS injection as balanced despite varied and unbalanced conditions. OCNN builds networks by self-constructive methods. Each training session enables the addition of new hidden layers and neurons inside each layer. The OCNN network compares the error value associated with the training results to the error value associated with the temporary best network (TBN). Throughout each training session, this comparison is made to determine the network with the lowest error value or the global best network (GBN). The frequent irradiation fluctuation indicated that the system often stayed in a transient rather than a steady-state. In high transient conditions, the performance of the proposed controlling method had been tested in simulations. The result revealed that the OCNN controller obtains the lowest peak values under high transient conditions, namely 2.62% for PCU and 6.73%, 7.33%, and 6.63% for THDi, respectively, at phases A, B, and C.
Gov't Doc #: KODEPRODI1910201#Teknik Elektro
URI: https://repository.unej.ac.id/xmlui/handle/123456789/111048
Appears in Collections:LSP-Jurnal Ilmiah Dosen



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.