Title: Modeling Battery Monitoring System (Bms) On Photovoltaic Based Moving Average And Autoregressive Integrated Moving Average Model (Arima)
Authors: MUHTADI, Ahmad
KALOKO, Bambang Sri
HARDIANTO, Triwahju
Keywords: ARIMA
Moving Average
BMS
Photovoltaic
Modeling
Issue Date: 21-Sep-2022
Publisher: International Journal of Science, Engineering and Technology
Abstract: Battery Management System (BMS) is a tool used to monitor and manage battery conditions. In battery modeling to engineer batteries, it is necessary to identify the parameters. Accurate modeling and identification of parameters are required to create a reliable BMS system. In this study, battery modeling was carried out using a moving average and ARIMA model because it was able to predict the shape of the data to resemble its original form and was significant. Meanwhile, the identification of parameters is carried out using test data that has been carried out on a dataset of power consumption for 1 year. The results obtained by the ARIMA model which has the best accuracy for predicting BMS, namely the MSE test: 0.076 with a relatively small error deviation value.