Show simple item record

dc.contributor.authorALIFFIAN, Bayu
dc.date.accessioned2023-05-26T02:32:24Z
dc.date.available2023-05-26T02:32:24Z
dc.date.issued2023-03-17
dc.identifier.nim171910201081en_US
dc.identifier.urihttps://repository.unej.ac.id/xmlui/handle/123456789/116522
dc.description.abstractThe main components of an electric power system do not escape the three components covering the generating system, transmission network and distribution system. These three components do not escape the need for a security or institution that handles or oversees the flow of electrical energy in an area. PT PLN Persero itself is a state-owned enterprise that oversees and oversees the distribution of electrical energy from the process of generating electricity to distributing electricity to consumers throughout Indonesia. which certainly requires a large enough source of electrical energy supply. So that a research on the reliability of the 20 KV medium voltage distribution system network is focused on at PT PLN UP3 West Surabaya which has one of the feeders, namely the An Nur feeder. This study discusses the reliability of the 20 KV medium voltage distribution system network by comparison with SPLN 59 of 1985. The method used is the Reliability Index Assessment method where supporting data is needed in the research obtained from PT PLN UP3 West Surabaya including data on An Nur feeder number of subscribers , power capacity, as well as the single line diagram so that in data processing it is hoped that the output reliability index of the distribution system SAIDI, SAIFI, CAIDI will be obtained. Then based on the single line diagram of the An Nur feeder, a simulation will be modeled on ETAP 12.6.0. The results of this study for the reliability value of the conventional calculation system obtained a SAIFI value of 0.062798 disturbances/year, SAIDI with a value of 0.188395 hours/year, and CAIDI of 3 disturbances/hour/year. Inen_US
dc.language.isootheren_US
dc.publisherTekniken_US
dc.subjectSAIDI, SAIFI, KEANDALAN SISTEM 20KVen_US
dc.titleAnalisis Keandalan Sistem Jaringan Distribusi Tegangan Menengah 20KV pada Penyulang an Nur PT. Pln UP3 Surabaya Barat dengan Metode Realibility Index Assesment ( Ria)en_US
dc.typeSkripsien_US
dc.identifier.prodiTeknik Elektroen_US
dc.identifier.pembimbing1Dr.Triwahju Hardianto, S.T., M.T.en_US
dc.identifier.pembimbing2Widjonarko, S.T., M.T.en_US
dc.identifier.finalizationFinalisasi tanggal 26 Mei 2023_M.Arif Tarchimansyahen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record