Please use this identifier to cite or link to this item: https://repository.unej.ac.id/xmlui/handle/123456789/69291
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorSumardi-
dc.contributor.advisorBudi Utomo, Satriyo-
dc.contributor.authorIrawan, Singgih-
dc.date.accessioned2015-12-30T03:28:52Z-
dc.date.available2015-12-30T03:28:52Z-
dc.date.issued2014-
dc.identifier.urihttp://repository.unej.ac.id/handle/123456789/69291-
dc.description.abstractThis research is conducted to make a measurement tool for non-invasive kidney disruption patients. The detection is done without touching the kidney disruption patients’ body. Urine with the reduction of positive protein will produce turbidity or discoloration that can be affected the light intensity which is captured by photodiode censor. Variation of voltage which is produced by the censor will be converted into digital signals by ADC and will be displayed through a computer in the form of database system. From the result of the laboratory testing, it said that the value which is generated if the patients were negative in kidney disruption, the value was 154 ppm, whereas if the patients were positive in kidney disruption, the value became 74 ppm. So I took the standardize for my observation tool if the value is above 100 ppm, it is negative and if the value is below 100 ppm, it is positive. The software that is used in this research consists of two parts, software for microcontroller program by using Bascom AVR, and software in the computer to show the result of censor perusal by using Python database PHPMyadmin. The perusal ADC value will be converted to ppm in microcontroller. Phyton displayed the chart. Next, the data is sent to the database PHPMyadmin. The testing of the normal patient was 0 (negative), 154 ppm and the sick patient was 180 (positive), 76 ppm. The range of 100 ppm as midpoint references, if the value of ppm is more than 100, the protein content is negative, and if the value of ppm is less than 100, the protein content is positive. The testing in the laboratory uses two samples of urine, from the normal and sick patient.en_US
dc.language.isoiden_US
dc.publisherUNEJ Pressen_US
dc.subjectProtein contenten_US
dc.subjectADCen_US
dc.subjectdatabasesen_US
dc.subjectppmen_US
dc.titlePerancangan Alat Ukur Kadar Protein Dengan Tingkat Kekeruhan Urine Berbasis Database Systemen_US
dc.typeStudent Paperen_US
Appears in Collections:SRA- Sains And Technology

Files in This Item:
File Description SizeFormat 
Singgih Irawan.pdf129.23 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.